Danfoss iC7-Automation Drive Fault Codes:
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 0x21FF / 4372 Current Injection Limit | Cause: The time limit for the short term current injection has been exceeded. Remedy:
|
| 0x2212 / 4374 DC-link Resonance | Cause: A resonance on the DC link with excessive RMS current values has been detected. |
| 0x2221 / 4384 Thermal Overload Rectifier | Cause: The rectifier is thermally overloaded. Mission profile is too demanding. |
| 0x2222 / 4373 DC-link Overcurrent | Cause: An overcurrent on the main DC-link capacitors has been detected. |
| 0x2310 / 5170 Current Limit Timeout | Cause: The drive has exceeded the allowed time in current limit. |
| 0x2311 / 4097 Inverter Overload | Cause: Thermal overload is detected in the inverter of the drive. Remedy:
|
| 0x2311 / 4368 Output Current High 0 | Cause: The output current of the drive has exceeded its normal range at low speed. Shock load or too fast acceleration with high-inertia loads can cause this fault. Remedy:
|
| 0x2311 / 4369 Output Current High 1 | Cause: The output current of the drive has exceeded its normal range. Shock load or too fast acceleration with high-inertia loads can cause this fault. Remedy:
|
| 0x2311 / 4375 Excessive Current Limiting | Cause: The output current of the drive has exceeded the current limit multiple times. Remedy:
|
| 0x2311 / 4377 Smart Derating Fault | Cause: A Smart Derating fault is detected. The load is too demanding for the current derating level. Remedy:
|
| 0x2311 / 4380 Current Limit Setting Fault | Cause: The actual current limit setting is too high relative to the selected constant control frequency level. Remedy:
|
| 0x2330 / 4352 Ground Fault 0 | Cause: A high-impedance ground fault is detected on the output. Remedy:
|
| 0x2330 / 4353 Ground Fault 1 | Cause: A high-impedance ground fault is detected on the output. Remedy:
|
| 0x2330 / 4354 Ground Fault 2 | Cause: A low-impedance ground fault is detected on the output. Remedy:
|
| 0x2330 / 4355 Ground Fault 21 | Cause: A high or low-impedance ground fault is detected on the output. Remedy:
|
| 0x2340 / 4356 Inverter Short Circuit | Cause: A short circuit at the inverter output is detected. Remedy:
|
| 0x2340 / 4370 Output Current High 2 | Cause: A critical output overcurrent has been detected. Remedy:
|
| 0x2340 / 4649 Desat Gate Driver | Cause: The gate driver has detected desaturation condition. |
| 0x23FD / 4182 Motor Sync Loss | Cause: Motor Loss of Synchronization. |
| 0x23FE / 4371 Current Imbalance | Cause: A current imbalance between paralleled power units has been detected. |
| 0x23FF / 4175 Motor Disconnected | Cause: The motor is disconnected. |
| 0x23FF / 4176 Missing Motor Phase | Cause: A missing motor phase is detected. Remedy:
|
| 0x3110 / 4164 Grid Voltage High | Cause: Grid voltage (RMS) above the normal operating range is detected. |
| 0x3120 / 4165 Grid Voltage Low | Cause: A grid voltage (RMS) below the normal operating range is detected. |
| 0x3130 / 4160 Missing Grid Phase | Cause: A missing phase is detected on the grid side. Remedy:
|
| 0x3140 / 4161 Grid Frequency Out of Range | Cause: A grid frequency outside the normal operating range is detected. |
| 0x31FD / 4162 Grid Voltage Spikes | Cause: Excessive spikes on the grid voltage have been detected. |
| 0x31FE / 4163 Grid Imbalance | Cause: A large imbalance of the grid voltages is detected. Remedy:
|
| 0x31FF / 4166 Grid Synchronization Error | Cause: The drive is unable to maintain the synchronization to the grid voltage. |
| 0x3211 / 4144 DC-link Voltage High 2 | Cause: The voltage of the DC link is above the normal operating range. Can be caused by too fast motor braking or grid transients. Remedy:
|
| 0x3212 / 4145 DC-link Voltage High 1 | Cause: The voltage of the DC link is above the normal operating range and has reached a critical level. Can be caused by too fast motor braking or grid transients. Remedy:
|
| 0x3221 / 4146 DC-link Voltage Low | Cause: The DC-link voltage is below the normal operating range. Remedy:
|
| 0x32FE / 4148 DC-link Imbalance | Cause: An imbalance across the DC-link capacitors is detected. The imbalance can be caused by a component fault of the DC link. Remedy:
|
| 0x32FE / 4149 DC-link Short Circuit | Cause: An internal short circuit is detected in the DC link. Remedy:
|
| 0x32FE / 4150 DC Capacitor Short Circuit | Cause: A short circuit in a DC-link capacitor is detected. Remedy:
|
| 0x32FE / 4151 DC-link Short Circuit 2 | Cause: A short circuit in the DC-link capacitor is detected. Remedy:
|
| 0x32FF / 4147 DC-link Voltage Ripple | Cause: Excessive voltage ripple has been detected on the main DC-link capacitors. This can be caused by an imbalance of the grid. Remedy:
|
| 0x4110 / 4099 Ambient Temp. High | Cause: The ambient temperature is too high. Remedy:
|
| 0x4210 / 4103 Inverter Temp. Limit | Cause: The temperature of the inverter heat sink is at the upper limit of the normal temperature range. Remedy:
|
| 0x4210 / 4104 Inverter Temp. High 1 | Cause: The temperature of the inverter heat sink has exceeded the normal temperature level. Remedy:
|
| 0x4210 / 4105 Inverter Temp. High 2 | Cause: The temperature of the inverter heat sink has reached a critical level. Remedy:
|
| 0x4210 / 4107 Brake Chopper Temp. Limit | Cause: The temperature of the brake chopper heat sink is at the upper limit of the normal temperature range. Remedy:
|
| 0x4210 / 4108 Brake Chopper Temp. High 1 | Cause: The temperature of the brake chopper heat sink has exceeded the normal temperature range. Remedy:
|
| 0x4210 / 4109 Brake Chopper Temp. High 2 | Cause: The temperature of the brake chopper heat sink has reached a critical level. Remedy:
|
| 0x4210 / 4110 IGBT Temp. High | Cause: An inverter IGBT overtemperature has been detected. Remedy:
|
| 0x4210 / 4113 Rectifier Temp. Limit | Cause: The temperature of the rectifier heat sink is at the upper limit of the normal temperature range. Remedy:
|
| 0x4210 / 4114 Rectifier Temp. High 1 | Cause: The temperature of the rectifier heat sink has exceeded the normal temperature range. Remedy:
|
| 4115 (0x4210) Rectifier Temp. High 2 | Cause: The temperature of the rectifier heat sink has reached a critical level. Remedy:
|
| 4125 (0x4210) IGBT Temp. High | Cause: An inverter IGBT temperature has reached a critical value. Remedy:
|
| 4200 (0x4210) Power Option Temp. High 1 | Cause: The temperature of a power option has exceeded the normal temperature range. Remedy:
|
| 4201 (0x4210) Power Option Temp. High 2 | Cause: The temperature of a power option has reached a critical level. Remedy:
|
| 4203 (0x4210) Power Option Temp. Limit | Cause: The temperature of a power option component is at the upper limit of the normal temperature. Remedy:
|
| 4102 (0x4220) Ambient Temp. Low | Cause: The drive is operated at a too low ambient temperature. Remedy:
|
| 4106 (0x4220) Brake Chopper Temp. Low | Cause: The temperature of the brake chopper heat sink is too low. Remedy:
|
| 4112 (0x4220) Rectifier Temp. Low | Cause: The temperature of the rectifier heat sink is too low. Remedy:
|
| 4202 (0x4220) Power Option Temp. Low | Cause: The temperature of a power option component is too low. Remedy:
|
| 5132 (0x4280) Temp. Protection 1 | Cause: Temperature protection 1 is triggered. The temperature has exceeded the configured value. |
| 5133 (0x4280) Temp. Protection 2 | Cause: Temperature protection 2 is triggered. The temperature has exceeded the configured value. |
| 5134 (0x4280) Temp. Protection 3 | Cause: Temperature protection 3 is triggered. The temperature has exceeded the configured value. |
| 5135 (0x4280) Temp. Protection 4 | Cause: Temperature protection 4 is triggered. The temperature has exceeded the configured value. |
| 5136 (0x4280) Temp. Protection 5 | Cause: Temperature protection 5 is triggered. The temperature has exceeded the configured value. |
| 5137 (0x4280) Temp. Protection 6 | Cause: Temperature protection 6 is triggered. The temperature has exceeded the configured value. |
| 4117 (0x4310) Power Unit Temp. Limit | Cause: The internal air temperature of the drive is at the upper limit of the normal temperature range. Remedy:
|
| 4118 (0x4310) Power Unit Temp. High 1 | Cause: The internal air temperature of the drive has exceeded its normal temperature range. Remedy:
|
| 4119 (0x4310) Power Unit Temp. High 2 | Cause: The internal air temperature of the drive has reached a critical value. Remedy:
|
| 4121 (0x4310) Control Board Temp. Limit | Cause: The temperature of the control board is at the upper limit of the normal temperature range. Remedy:
|
| 4122 (0x4310) Control Board Temp. High 1 | Cause: The temperature of the control board has exceeded its normal temperature range. Remedy:
|
| 4123 (0x4310) Control Board Temp. High 2 | Cause: The temperature of the control board has reached a critical level. Remedy:
|
| 4116 (0x4320) Power Unit Temp. Low | Cause: The internal air temperature of the drive is below the normal operating range. The drive is operated at a too low ambient temperature. Remedy:
|
| 4120 (0x4320) Control Board Temp. Low | Cause: The temperature of the control board is below the normal temperature range. The drive is operated at a too low ambient temperature. Remedy:
|
| 5240 (0x4380) Cooling Monitor | Cause: The cooling signal is missing. |
| 4124 (0x43FF) Break Chopper Temperature Imbalance | Cause: There is a temperature imbalance between 1 or more brake chopper IGBTs. |
| 4126 (0x43FF) IGBT Temperature Imbalance | Cause: There is a temperature imbalance between 1 or more IGBTs. |
| 4127 (0x43FF) IGBT Temperature Imbalance | Cause: An excessive thermal imbalance between the IGBT modules has been detected. Remedy:
|
| 4131 (0x43FF) Temperature Imbalance Brake IGBT | Cause: There is a temperature imbalance between 1 or more brake chopper IGBTs. |
| 4132 (0x43FF) IGBT temperature delta | Cause: There is a temperature imbalance between 1 or more IGBTs. |
| 4204 (0x43FF) Power Option Temp. Imbal. 1 | Cause: The thermal imbalance between the power option components exceeds the normal operating range. |
| 4205 (0x43FF) Power Option Temp. Imbal. 2 | Cause: An excessive thermal imbalance between power option components has been detected. |
| 4206 (0x43FF) Power Option Temp. Imbal. Limit | Cause: The thermal imbalance between the power option components is at the upper limit of the normal operating range. |
| 5400 (0x4480) AHF High Temp. Derate | Cause: A too high temperature is detected in the connected AHF (Advanced Harmonic Filter). Output has been derated to 50%. |
| 5401 (0x4480) AHF High Temp. Stop | Cause: A too high temperature has been detected in the connected AHF (Advanced Harmonic Filter). Operation of the drive has been stopped. |
| 4640 (0x5112) 24V Supply Fault | Cause: The 24V supply is outside its normal operating range. |
| 4642 (0x5114) 3.3V Supply Low | Cause: The voltage of the internal 3.3V supply is below its normal operating range. |
| 4643 (0x5115) 28V Supply Low | Cause: The voltage of the internal 28V supply is below its normal operating range. |
| 4644 (0x51FE) Gate Driver Voltage Fault | Cause: The gate driver supply voltage is outside its normal operating range. |
| 4653 (0x51FE) Gate Driver Fault | Cause: A gate driver fault is detected or a link to the gate driver is broken. |
| 4645 (0x51FF) Power Board Supply Fault | Cause: A power supply fault on the power board has been detected. |
| 4646 (0x51FF) Power Supply Voltage | Cause: A power supply voltage is outside its normal operating range. |
| 4378 (0x5210) Current Sensor Fault | Cause: A defective current sensor or an error in the calibration of the current sensors has been detected. |
| 5173 (0x5400) Power Limit Timeout Regenerative | Cause: The drive has exceeded the allowed time in power limit. |
| 5174 (0x5400) Power Limit Timeout Motoring | Cause: The drive has exceeded the allowed time in power limit. |
| 4641 (0x54EB) 24V Backup Mode | Cause: The drive is in 24V backup mode. The control section (including parameter configurations) and installed options are kept operational. |
| 4647 (0x54EC) Function Disabled | Cause: The protection logic keeps the trip active until the configuration of the power unit protection levels is ready. |
| 4128 (0x54ED) Control Fan Failure | Cause: The control board cooling fan is not running at the commanded speed. |
| 4129 (0x54EE) Main Fan Failure | Cause: The main cooling fan is not following its reference speed. Remedy:
|
| 4133 (0x54EE) LCL Fan Speed Fault | Cause: LCL cooling fan not tracking commanded output. |
| 4130 (0x54EF) Internal Fan Failure | Cause: The internal fan is running below its reference speed. Remedy:
|
| 4628 (0x54F0) STO Activated | Cause: The Safe Torque-Off (STO) is activated and an unintended restart is prevented until the STO-request has been reset. |
| 4629 (0x54F0) STO Fault Ch. A | Cause: The Safe Torque-Off (STO) is activated due to a discrepancy fault: Channel A is not activated, while channel B is activated. |
| 4630 (0x54F0) STO Fault Ch. B | Cause: The Safe Torque-Off (STO) is activated due to a discrepancy fault: Channel B is not activated, while channel A is activated. |
| 4790 (0x5530) Control Data Error | Cause: A data error is detected in the control data database EEPROM. |
| 4791 (0x5530) Invalid PUD | Cause: A data error has been detected in the power unit database EEPROM. |
| 5260 (0x6180) Event Simulation | Cause: The event with the number 5260 is simulated. |
| 5264 (0x6180) Event Simulation SS2 Inst 1 | Description: Event simulation SS2 Instance 1. |
| 5265 (0x6180) Event Simulation SS2 Inst 2 | Description: Event simulation SS2 Instance 2. |
| 4980 (0x6181) A Digital Input terminal is unknown by system | Cause: A digital input terminal has been selected that is unknown by system. Maybe an option has been moved or removed. |
| 4981 (0x6181) A Digital Output terminal is unknown by system | Cause: A digital output terminal has been selected that is unknown by system. Maybe an option has been moved or removed. |
| 4982 (0x6181) An Analog Input terminal is unknown by system | Cause: An analog input terminal has been selected that is unknown by system. Maybe an option has been moved or removed. |
| 4983 (0x6181) An Analog Output terminal is unknown by system | Cause: An analog output terminal has been selected that is unknown by system. Maybe an option has been moved or removed. |
| 4984 (0x6181) A Digital Output occupied | Cause: A digital output is in use by another function or fieldbus. If a Fieldbus has taken control over a terminal, it has priority over parameter selection. |
| 4985 (0x6181) An Analog Output occupied | Cause: An analog output is in use by another function or fieldbus. If a Fieldbus has taken control over a terminal, it has priority over parameter selection. |
| 4853 (0x61F4) StartupOccurrence | Description: This occurrence masks over various occurrences that might be active during startup, that we dont want to show the end user. |
| 4854 (0x61F5) Reset By Demand | Description: Drive reset is requested by user, and will be performed shortly. |
| 4638 (0x61F6) Drive to Drive Connection Lost | Cause: Drive to drive connection is lost. |
| 4800 (0x61F7) Low Storage Space | Cause: The available storage space for the file system is low. |
| 4801 (0x61F7) Data Logger Storage | Cause: Volume restriction limits are preventing additional data logger capture files from being stored. |
| 4802 (0x61F7) Event Logger Storage | Cause: Volume restriction limits are preventing additional event log capture files from being stored. |
| 4832 (0x61F8) Node Discovery | Description: Node discovery and configuration are in progress. The modulation is inhibited. |
| 4833 (0x61F8) Node Commissioning | Description: Nodes are being commissioned. |
| 4834 (0x61F8) Node Missing | Cause: A previously commissioned node is no longer available. The drive is waiting for the node to be available. Remedy:
|
| 4855 (0x61F9) Internal Fault | Cause: An internal fault has been detected. Remedy:
|
| 4856 (0x61F9) Internal Fault | Cause: An internal fault has been detected (connection from controller). Remedy:
|
| 4816 (0x61FA) PLC Task Overrun | Cause: The high CPU load is inhibiting normal operation of the application (PLC task overrun). |
| 4817 (0x61FA) PLC Runtime Error | Cause: The PLC runtime has stopped responding. The application has been halted. |
| 4600 (0x61FB) Option Communication Fault | Cause: A fault of the communication with an option has been detected. Remedy:
|
| 4601 (0x61FB) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4602 (0x61FB) Option Communication Fault | Cause: A fault of the communication with an option has been detected. Remedy:
|
| 4607 (0x61FB) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4631 (0x61FB) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4632 (0x61FB) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4605 (0x61FC) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4606 (0x61FC) Internal Communication Fault | Cause: An internal communication fault has been detected. Remedy:
|
| 4639 (0x61FC) High Speed Bus Sync Error | Cause: Internal error detected with high-speed bus connection to parallel control unit. |
| 4648 (0x61FC) High Speed Bus Error | Cause: Internal error detected with high-speed bus connection to parallel control unit. |
| 4858 (0x61FC) Internal Fault | Cause: An internal fault has been detected. The power system has not received the required reference for modulation. Remedy:
|
| 4859 (0x61FC) Internal Fault | Cause: An internal fault (connection from power system) has been detected. Remedy:
|
| 4860 (0x61FC) Unexpected Time Adjust | Cause: An internal fault (unexpected time adjustment) has been detected. Remedy:
|
| 4861 (0x61FC) Synchronization Fault | Cause: An internal fault (time synchronization error between controller and power system) has been detected. Remedy:
|
| 4862 (0x61FC) PDS | Cause: Internal error detected with high-speed bus connection from controller. |
| 4863 (0x61FC) Internal Fault | Cause: An internal fault (connection with power system) has been detected. Remedy:
|
| 4857 (0x61FD) Software Update | Description: The drive is currently performing an update of the software. |
| 4567 (0x61FF) Restore Status | Description: Provides information about the restore operation of a setting. |
| 5301 (0x6320) Invalid Control Config | Cause: An invalid control configuration is preventing operation. |
| 5302 (0x6320) Start Blocked | Cause: Start of the motor is blocked. Remedy:
|
| 5220 (0x7080) Brake Feedback Wrong State | Cause: Mechanical brake feedback is in a wrong state. Feedback state should reflect state of brake, except during opening or closing phases. |
| 5221 (0x7080) Brake Priming Timeout | Cause: Brake priming has timed out. The drive could not produce the configured priming torque to open the brake safely. |
| 5222 (0x7080) Brake Feedback Timeout | Cause: Brake feedback has timed out. The feedback signal is indicating that the mechanical brake has not opened or closed within the configured time. |
| 5204 (0x7110) Brake Resistor Test Active | Description: The Brake Resistor Test is active. Normal run of the drive is not possible. |
| 5205 (0x7110) Brake Resistor Test Failed | Cause: The Brake Resistor Test was unsuccessful. Remedy:
|
| 5206 (0x7110) Brake Resistor Test Successful | Description: The test of the brake resistor is performed successfully. |
| 4403 (0x7111) Brake Ch. Switch Shorted | Cause: A short circuit of the brake chopper switch has been detected, which can be dangerous. Remedy:
|
| 4400 (0x7113) Brake Chopper Overload | Cause: A brake chopper overcurrent has been detected. Remedy:
|
| 4401 (0x7113) Brake Resistor Temp. High | Cause: The brake resistor temperature is too high. Remedy:
|
| 4402 (0x7113) Brake Resistor Missing | Cause: The brake resistor or its connection is missing. |
| 4404 (0x7113) Brake Failure | Cause: A brake failure is detected, further testing will clarify the failure source. Remedy:
|
| 4177 (0x7120) Motor Thermal Overload | Cause: A thermal overload of the motor has been detected. Remedy:
|
| 4178 (0x7120) Motor Speed High | Cause: The motor speed is above the normal operating range. |
| 5200 (0x7120) AMA Active | Cause: The AMA (Automatic Motor Adaptation) is active. Normal run of the motor is not possible. Remedy:
|
| 5201 (0x7120) AMA Motor Data | Cause: The motor data measurement of the AMA (Automatic Motor Adaptation) was unsuccessful. |
| 5202 (0x7120) AMA Motor Type | Cause: The motor type detection of the AMA (Automatic Motor Adaptation) was unsuccessful. |
| 5203 (0x7120) AMA Successful | Cause: The AMA (Automatic Motor Adaptation) has been performed successfully. |
| 5300 (0x7120) Invalid Motor Data | Cause: Invalid motor data is preventing operation. Remedy:
|
| 4179 (0x71FC) AMA Current Low | Cause: The nominal current of the motor is too low for accurate results of automatic motor adaptation (AMA). |
| 4181 (0x71FD) Low Motor Saliency For High Frequency Injection Mode | Cause: Motor saliency is too low for HF injection mode. |
| 4180 (0x71FE) Rotor Angle Detection Error | Cause: Rotor angle detection has failed. This might be as the motor is not suited to the drive or the motor is missing. |
| 4379 (0x71FF) CM Current High | Cause: An excessive common mode current has been detected in the LCL-filter. |
| 4417 (0x72FE) Feedback Option Fault | Cause: The Feedback Option is indicating a fault condition. |
| 4418 (0x7310) Bad Speed Feedback | Cause: Speed Feedback value is not reliable. |
| 5141 (0x7580) Control Panel Connection Lost | Cause: The connection to the control panel is lost. Control via control panel is released. |
| 5142 (0x7580) PC Connection Lost | Cause: The connection to the PC tool is lost. PC control is released. |
| 4256 (0x75FC) Address Conflict | Cause: The fieldbus has identified an Address Conflict on the network which made the device back off. |
| 4257 (0x75FC) Ethernet Cable Fault | Cause: At link down a measurement is done to measure the distance to the far end of the cable, indicating where the fault has occurred. This warning occurs at distances > 4 m and Link State Change Down. Actual distance shown in detailed info. |
| 4258 (0x75FC) Invalid Fieldbus Configuration | Cause: An issue due to an invalid configuration of the fieldbus connection has been detected. Features not supported by the device, mismatch between configured and actually available features or modules not available in the device. Remedy:
|
| 4260 (0x75FC) Redundant Controller Missing | Cause: One or more of the expected fieldbus controllers are missing. |
| 4261 (0x75FC) Fieldbus Topology Mismatch | Cause: The current fieldbus topology does not match the topology provided at commissioning time. |
| 4263 (0x75FC) Ethernet Link Status Changed | Cause: There has been detected a change of the Ethernet link status. Additional info has details about which port and state. |
| 4265 (0x75FC) Ethernet Redundancy Error | Cause: Primary or backup physical paths has been detected missing. |
| 4266 (0x75FC) X1 Cable Redundancy | Cause: Indicates that physical path from X1 interface to the controller is missing or wrongly configured. |
| 4267 (0x75FC) X2 Cable Redundancy | Cause: Indicates that physical path from X2 interface to the controller is missing or wrongly configured. |
| 4269 (0x75FC) Network Time Protocol | Cause: Information of Network Time Protocol server. Remedy:
|
| 4280 (0x75FC) Controller Not in Run | Cause: Controller not in RUN state. |
| 4281 (0x75FC) Interface Configuration Change | Cause: Interface configuration changed. Remedy:
|
| 4273 (0x75FD) No EtherCAT Connection | Cause: No EtherCAT communication is currently established. Will happen during start-up until first connection is established. Or if all connections has stopped (gracefully or disruptive). |
| 4282 (0x75FD) No Modbus TCP Connection | Cause: No Modbus RTU communication is currently established. Occurs during start-up until first connection is established, or if all connections has stopped (gracefully or disruptive). |
| 4277 (0x75FE) Loss of EtherCAT Connection | Cause: One or more of the fieldbus I/O connections has failed. This can happen when an established fieldbus I/O Connection has been disrupted. Remedy:
|
| 4283 (0x75FE) Loss of Modbus RTU Connection | Cause: One or more of the fieldbus I/O connections has failed. This can happen when an established fieldbus I/O connection has been disrupted. Remedy:
|
| 4278 (0x75FF) Primary Process Data Timeout | Cause: The fieldbus I/O data has not been updating any of the process data monitored by the primary process data monitor (Watchdog1). This can happen when the fieldbus has lost control or the current transferred I/O data is not valid. |
| 4279 (0x75FF) Secondary Process Data Timeout | Cause: The fieldbus I/O Data has not been updating any of the process data monitored by the secondary process data monitor (Watchdog2). This can happen when the fieldbus has lost control or the current transferred I/O data is not valid. |
| 5162 (0x8100) Alternate Control Place due to Fieldbus Timeout | Cause: Fieldbus process data timeout changed to alternate control place. |
| 5171 (0x8331) Torque Limit Timeout Motoring | Cause: The drive has exceeded the allowed time in torque limit. |
| 5172 (0x8331) Torque Limit Timeout Regenerative | Cause: The drive has exceeded the allowed time in torque limit. |
| 5210 (0x8400) Below Min. Speed | Cause: The Speed Monitor has detected that the speed is below the configured minimum speed. |
| 5290 (0x8400) Speed Too High | Cause: The speed monitor has detected that the speed is above the configured maximum. |
| 5292 (0x8400) Start Below Min. Speed | Cause: The start took too long. The speed has not reached the minimum speed within the time frame configured. |
| 4192 (0x8611) Position Following Error | Cause: The actual position is outside the allowed range of the position error window around a position demand value for longer than the position error delay. |
| 4193 (0x8612) Position Limit | Cause: Motor position is outside the allowed range [PositionMin, PositionMax]. |
| 4194 (0x8612) Position Command Rejected | Cause: Position command was rejected because of position software end limit. |
| 4195 (0x8612) Hardware End Limit | Cause: The positioning controller detected that the drive is exceeding the hardware end Limits. |
| 5230 (0x9080) Lost Load Detected | Cause: Drive is not detecting any load on the motor shaft. |
| 5270 (0xF004) Inertia Estimation Active | Cause: The drive is ready for performing the Inertia Estimation. Remedy:
|
| 5271 (0xF004) Inertia Estimation Failed | Cause: The Inertia Estimation failed. |
| 5272 (0xF004) Inertia Estimation Successful | Cause: Inertia Estimation has been performed successfully. |
| 5123 (0xFF01) External Exception 1 | Cause: External Exception 1. |
| 5124 (0xFF01) External Exception 2 | Cause: External Exception 2. |
| 4304 (0xFFFE) License Missing | Cause: A required license is missing. |
| 4349 (0xFFFF) Authenticity Error | Cause: Files authenticity verification error occurred. |
| 4350 (0xFFFF) Configuration Error | Cause: An invalid system configuration has been detected. |
| 4351 (0xFFFF) System Fault | Cause: A system fault has been detected. Remedy:
|
| 4357 (0xFFFF) Firmware Crash | Cause: A firmware crash occurred and detailed information is provided. |