Omron 3G3MX2-V2 Drive Fault Codes:
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| E01 Overcurrent protection (Constant speed) | Cause: Rapid load fluctuation, output short-circuit, or ground fault during constant speed. Remedy:
|
| E02 Overcurrent protection (Deceleration) | Cause: Rapid deceleration causing large current. Remedy:
|
| E03 Overcurrent protection (Acceleration) | Cause: Rapid acceleration, motor locked, torque boost too high, or PM motor adjustment issue. Remedy:
|
| E04 Overcurrent protection (Others) | Cause: DC injection braking power too high. Remedy:
|
| E05 Overload protection | Cause: The inverter output current exceeded limits (motor overload). Remedy:
|
| E06 Braking resistor overload protection | Cause: Usage rate of regenerative braking circuit exceeds value set in b090. Remedy:
|
| E07 Overvoltage protection | Cause: High DC voltage due to regenerative energy or high incoming voltage (>400VDC for 200V class / >800VDC for 400V class). Remedy:
|
| E08 EEPROM error | Cause: Error in built-in EEPROM due to external noise or abnormal temperature. Remedy:
|
| E09 Undervoltage | Cause: Incoming voltage drops below specified level; Control circuit failure. Remedy:
|
| E10 Current detector error | Cause: Error in the current detector. Remedy:
|
| E11 CPU error | Cause: Malfunction or error in built-in CPU. Remedy:
|
| E12 External trip | Cause: Multi-function input allocated to External Trip (12: EXT) turned ON. Remedy:
|
| E13 USP error | Cause: Power supply turned on while RUN signal was ON (when USP function selected). Remedy:
|
| E14 Grounding protection | Cause: Ground fault detected between inverter output and motor upon power on. Remedy:
|
| E15 Incoming overvoltage protection | Cause: Incoming voltage in overload state for 100s (DC voltage >390VDC for 200V / >780VDC for 400V). Remedy:
|
| E19 Temperature detection error | Cause: Cooling fin temperature detection system error (e.g., disconnection). Remedy:
|
| E21 Abnormal temperature | Cause: Main circuit temperature exceeds limit (high ambient temp, fan issue). Remedy:
|
| E22 CPU communication error | Cause: Malfunction in CPU during communications. Remedy:
|
| E25 Main circuit error | Cause: Error occurred in the main circuit board. Remedy:
|
| E26 Analog current input error | Cause: Excessive current flows through analog current input terminal FI. Remedy:
|
| E30 Driver error | Cause: Momentary overcurrent (350%+), abnormal temp, or drive power drop detected by driver IC. Remedy:
|
| E35 Thermistor error | Cause: External thermistor detected abnormal temp or wiring issue. Remedy:
|
| E36 Brake error | Cause: Inverter cannot recognize ON/OFF status of brake within detection time (b124). Remedy:
|
| E37 Emergency shutoff | Cause: Safety input terminal GS1/GS2 active. Remedy:
|
| E38 Low speed overload protection | Cause: Overload detected in extremely low speed range (0.2 Hz or lower). Remedy:
|
| E40 Digital Operator connection failure | Cause: Disconnection communicating with remote Digital Operator. Remedy:
|
| E41 Modbus communication error | Cause: Timeout occurred (Communication Error C076 is set to Trip). Remedy:
|
| E43 to E45 DriveProgramming error | Cause: Program error. Remedy:
|
| E50 to E59 User trip | Cause: User trip executed via DriveProgramming. Remedy:
|
| E60 to E68 Option error | Cause: Error received from the option unit (e.g., EtherCAT). Remedy:
|
| E69 Option timeout | Cause: Timeout in communications between inverter and option unit. Remedy:
|
| E80 Encoder disconnection | Cause: Encoder wiring disconnected or improperly connected. Remedy:
|
| E81 Overspeed | Cause: Motor rotation speed exceeds Maximum Frequency x Overspeed Error Level. Remedy:
|
| E83 Position control range trip | Cause: Current position out of range set in Position Limit Setting (P072, P073). Remedy:
|
| E99 STO internal fault error | Cause: Fault detected in STO input terminal or internal safety circuit. Remedy:
|