Parker AC690+ Plus Drive Fault Codes:
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| OVERVOLTAGE The drive internal dc link voltage is too high | Cause: High voltage conditions detected. Remedy:
|
| UNDERVOLTAGE The drive internal dc link voltage is too low | Cause: Low voltage conditions detected. Remedy:
|
| OVERCURRENT The motor current being drawn from the drive is too high | Cause: Current limits exceeded due to load or wiring issues. Remedy:
|
| HEATSINK The drive heatsink temperature is too high | Cause: Thermal overload of the drive unit. Remedy:
|
| EXTERNAL TRIP User trip caused via control terminals | Cause: External signal missing. Remedy:
|
| INPUT 1 BREAK A signal break has been detected on analog input 1 (terminal 1) | Cause: 4-20mA signal loss detected. Remedy:
|
| INPUT 2 BREAK A signal break has been detected on analog input 2 (terminal 2) | Cause: 4-20mA signal loss detected. Remedy:
|
| MOTOR STALLED The motor has stalled (not rotating) | Cause: Motor unable to turn under load. Remedy:
|
| INVERSE TIME The inverse time current limit is active | Cause: Prolonged overcurrent condition. Remedy:
|
| BRAKE RESISTOR External dynamic braking resistor has been overloaded | Cause: Excessive energy dumped to resistor. Remedy:
|
| BRAKE SWITCH Internal dynamic braking switch has been overloaded | Cause: Excessive energy dumped to brake circuit. Remedy:
|
| OP STATION Keypad has been disconnected from drive whilst drive is running in local control | Cause: Communication loss with HMI. Remedy:
|
| LOST COMMS Communications Failure | Cause: Timeout detected. Remedy:
|
| CONTACTOR FBK Contactor Feedback Error | Cause: Logic mismatch. Remedy:
|
| SPEED FEEDBACK Speed deviation detected | Cause: Control loop error. Remedy:
|
| AMBIENT TEMP The ambient temperature in the drive is too high | Cause: Environment too hot. Remedy:
|
| MOTOR OVERTEMP The motor temperature is too high | Cause: Thermal overload of the motor. Remedy:
|
| CURRENT LIMIT Current exceeds 180% of stack rated current for 1 second | Cause: Shock loads. Remedy:
|
| 24V FAILURE The 24V customer output has fallen below 17V | Cause: Overload on auxiliary supply. Remedy:
|
| TRIP 19 Reserved | Cause: Reserved. Remedy:
|
| LOW SPEED OVER I The motor is drawing too much current (>100%) at zero output frequency | Cause: Excessive magnetizing current. Remedy:
|
| PHASE FAIL One or more phases of the 3-phase supply is missing | Cause: Input power loss. Remedy:
|
| ENCODER 1 FAULT Encoder Error | Cause: Encoder module signal error. Remedy:
|
| DESAT (OVER I) Instantaneous overcurrent | Cause: Hardware protection trip. Remedy:
|
| VDC RIPPLE The dc link ripple voltage is too high | Cause: Supply imbalance. Remedy:
|
| BRAKE SHORT CCT Brake resistor overcurrent | Cause: Low resistance. Remedy:
|
| OVERSPEED Speed limit exceeded | Cause: Speed feedback has exceeded the THRESHOLD for a period greater than DELAY. Remedy:
|
| ANALOG INPUT ERR Analog Input Signal Error | Cause: Signal out of range. Remedy:
|
| TRIP 29 Reserved | Cause: Reserved. Remedy:
|
| TRIP 30 Reserved | Cause: Reserved. Remedy:
|
| UNKNOWN An unknown trip | Cause: Unknown system error. Remedy:
|
| MAX SPEED LOW Autotune Error: MAX SPEED RPM limits speed to less than nameplate value | Cause: Configuration error during Autotune. Remedy:
|
| MAINS VOLTS LOW The mains input voltage is not sufficient to carry out the Autotune | Cause: Supply sag during test. Remedy:
|
| NOT AT SPEED The motor was unable to reach the required speed to carry out the Autotune | Cause: Mechanical or Data issue. Remedy:
|
| MAG CURRENT FAIL Unable to find suitable magnetising current | Cause: Motor data mismatch. Remedy:
|
| NEGATIVE SLIP F Autotune has calculated a negative slip frequency | Cause: Data entry error. Remedy:
|
| TR TOO LARGE Calculated rotor time constant too large | Cause: Calculation out of bounds. Remedy:
|
| TR TOO SMALL Calculated rotor time constant too small | Cause: Calculation out of bounds. Remedy:
|
| MAX RPM DATA ERR MAX SPEED RPM is set outside range of Autotune data | Cause: Data unavailable for new speed range. Remedy:
|
| STACK TRIP Drive hardware trip | Cause: Critical hardware protection. Remedy:
|
| LEAKGE L TIMEOUT Leakage inductance measurement timeout | Cause: Unable to achieve required test current. Remedy:
|
| POWER LOSS STOP Power Loss Stop sequence ended | Cause: Sequence completion. Remedy:
|
| MOTR TURNING ERR Motor moving at start of Autotune | Cause: Motor not stationary. Remedy:
|
| MOTR STALLED ERR Motor unable to rotate during Autotune | Cause: Mechanical blockage. Remedy:
|