OVERSPEED
Motor overspeed – the speed feedback signal has exceeded 125% of rated speed. |
Cause:
- Badly adjusted speed loop.
- Note: Alarm only operates with encoder or armature volts feedback selected.
Remedy:
- Adjust speed loop settings.
- Note: Alarm time delay is 50 milliseconds.
|
MISSING PULSE
A missing pulse from the 6-pulse armature current waveform. (Only enabled when motor loading exceeds 1.5 times the DISCONTINUOUS parameter). |
Cause:
- Firing plug failure.
- Connection failure.
- Firing circuit connector problems during motoring operation.
Remedy:
- Check firing plug and connections.
- Note: We recommend fusing the armature circuit if regenerative operation is intended.
- Alarm time delay: 60 seconds.
|
FIELD OVER I
The motor field current has exceeded 120% of the calibrated value. |
Cause:
- External field has incorrect supply phases applied.
- (Alarm only operates with field current control mode selected).
Remedy:
- Check external field supply phases.
- Alarm time delay: 10 seconds.
|
HEATSINK TRIP
The Drive heatsink temperature is too high. |
Cause:
- Ambient air temperature is too high.
- Poor ventilation or spacing between Drives.
- Fan failure.
- Blocked ventilation slots or clogged air filters.
- Excessive armature current.
Remedy:
- Check fuse on power board.
- Check for wrong fan rotation (models above 70A bridge rating).
- Clean ventilation slots and filters.
- Check nominal armature current on nameplate against current calibration.
- Note: The stack must be allowed to cool in order to re-start the Drive.
|
THERMISTOR
The motor temperature is too high. |
Cause:
- Inadequate ventilation.
- Blower failure.
- Excessive armature current.
Remedy:
- Check blower direction and air filters (clogged).
- Check nominal armature current on nameplate against current calibration.
- Allow motor to cool to re-start.
|
OVER VOLTS (VA)
Motor armature voltage has exceeded 120% of rated volts. |
Cause:
- Loose armature connection.
- Badly adjusted field voltage setting.
- Badly adjusted field current loop, field-weakening bemf loop, or speed loop.
Remedy:
- Secure armature connections.
- Adjust field and speed loop settings.
|
SPEED FEEDBACK
Difference between speed feedback and armature voltage feedback is greater than SPDFBK ALM LEVEL. |
Cause:
- Analog tacho feedback polarity incorrect (terminals G3 and G4).
- The ENCODER SIGN parameter’s polarity is incorrect.
- Disconnection of wiring, including fibre optics.
- Armature voltage calibration not suitably reduced when running at reduced field currents.
- Tachogenerator failure or coupling failure.
Remedy:
- Check tacho polarity and wiring.
- Check Encoder Sign parameter.
- Inspect fibre optics.
|
ENCODER FAILED
No speed feedback signal. |
Cause:
- SPEED FBK SELECT parameter is set to ENCODER but optional Encoder board is not fitted.
- Fibre optic cable damage or incorrect bend radius.
Remedy:
- Check fibre optic cable for damage.
- Refer to Microtach handbook for operating length.
- Check cable and connections on wire-ended encoder.
|
FIELD FAIL
Field current is less than 6% (Current Control mode) or 50mA (Voltage Control mode). |
Cause:
- Open circuit motor field.
- Faulty operation of field controller.
- Missing AC supply to onboard field regulator.
Remedy:
- Check connection and measure field resistance.
- Check connections FL1 & FL2 for line-to-line voltage.
- If no field supply required (e.g. permanent magnet motor), set FIELD ENABLE parameter to DISABLED.
|
3-PHASE FAILED
3-phase supply failure. |
Cause:
- Total failure of supply or missing phase.
- Blown fuses (high-speed thyristor stack or power chassis coding).
- Incorrect mains voltage for the controller.
Remedy:
- Check supply to the controller.
- Check protection fuses.
- Verify mains voltage against Product Code.
|
PHASE LOCK
Supply frequency is outside the frequency band limits 45 – 65Hz. |
Cause:
- Supply frequency issue.
- Synchronisation errors caused by distorted supply.
Remedy:
|
5703 RCV ERROR
Invalid data received via P3 port from another Drive. |
Cause:
- Communication error on P3 port.
- (Alarm only operates when MODE parameter is set to 5703 SLAVE).
Remedy:
- Check connections on P3 port.
|
STALL TRIP
Motor stationary with current exceeding STALL THRESHOLD for longer than delay. |
Cause:
- Motor is stalled while current is high.
- (Alarm only operates when STALL TRIP parameter is enabled).
Remedy:
- Remove mechanical blockage or adjust stall parameters.
|
OVER I TRIP
Current feedback value has exceeded 280% of rated current. |
Cause:
- Motor armature windings failure.
- Badly tuned current loop.
- Faulty Drive.
Remedy:
- Check insulation resistance of armature windings.
- Tune current loop.
- Contact Parker if Drive is faulty.
|
ACCTS FAILED
AC current transformer plug connection to Drive power board missing. |
Cause:
- Plug missing or loose.
- Frame 5 only: Load imbalance between parallel power stacks.
Remedy:
- Check armature current transformer plug for correct installation.
|
AUTOTUNE ERROR
Error encountered during Autotune process (Speed > 20% or Field > 6%). |
Cause:
- Motor shaft was rotating or caused to rotate.
- Field current exceeded 6% during field-off Autotune.
- Drive to armature wiring open-circuit.
- Discontinuous current boundary > 200%.
- Large imbalance in three-phase supply voltages.
- Hardware fault on control board.
Remedy:
- Ensure motor shaft is stationary.
- Check wiring and supply voltages.
- Refer to “Control Loops – Manual Tuning” in manual.
|
AUTOTUNE ABORT
The Autotune sequence has been aborted. |
Cause:
- Coast Stop, Program Stop, Enable or Start Run terminal(s) disabled during sequence.
- AUTOTUNE parameter reset during sequence.
- Autotune sequence timed-out (approx 2 mins).
Remedy:
- Check enable/start signals and retry.
|
SEQ PRE READY
Coding not present. |
Cause:
- Power board or chassis issue.
Remedy:
- Replace power board or chassis.
|
CONTACTOR DELAY
The internal auxiliary 3-phase contactor failed to close. |
Cause:
- Internal contactor failure.
Remedy:
- Check the position of the Calibration Scaling Switch.
|
EXTERNAL TRIP
Customer alarm! (Trip operates if input open or high impedance). |
Cause:
- Device not wired to drive or device open circuited.
Remedy:
- Check C1 to C2 connections to drive.
- Connect C1 to C2 if customer device not fitted.
|
REMOTE TRIP
Remote trip activated. |
Cause:
- REM. SEQUENCE parameter Remote Trip flag set to zero.
Remedy:
- Check remote sequence parameters.
|
ENABLE LOW
Enable input is low. |
Cause:
- Local Mode run attempted with Enable input low.
Remedy:
- Check Enable input signal.
|
SEQUENCING
Internal sequencing error. |
Cause:
Remedy:
|
COMMS TIMEOUT
Remote comms timeout. |
Cause:
- Communication interruption.
Remedy:
- See COMMS TIMEOUT parameter in the SEQUENCING function block.
|
CONFIG ENABLED
Drive requested to start whilst in Configuration mode. |
Cause:
- Drive is in Configuration mode.
Remedy:
- Exit Configuration mode before starting.
|
CALIBRATION FAIL
Signal calibration fault. |
Cause:
- Hardware failure suspected.
Remedy:
- Power the unit off and on.
- If problem persists, contact Parker.
|
NO OP STATION
Keypad disconnected during local control. |
Cause:
- Keypad has been disconnected from Drive whilst Drive is running in local control.
Remedy:
- Reconnect keypad or switch control modes.
|
AUX SUPPLY
Auxiliary supply failure. |
Cause:
- Issue with aux supply or mains input.
Remedy:
- Check auxiliary supply and/or mains input.
|
COMMS FAULT CODE x
Communication hardware fault. |
Cause:
- Keypad faulty.
- Remote cable to keypad faulty.
- Drive firmware not running.
Remedy:
- Check keypad and cable.
- Check firmware status.
|
CRITICAL ERROR
xxxx::xxxxxxxx |
Cause:
Remedy:
|
(EEPROM) CHECKSUM FAIL
Parameters not saved, or are corrupted. |
Cause:
- Corrupted UDP file loaded.
- (Appears at power-up or end of “Upload” UDP Transfer).
Remedy:
- Press the E key.
- Perform a PARAMETER SAVE.
- Note: Drive will return to factory default values.
|
LANGUAGE CHECKSUM FAIL
Incorrect language selected, or corrupted. |
Cause:
- Corrupted UDP file loaded.
- (Appears at power-up or end of “Upload” UDP Transfer).
Remedy:
- Press the E key.
- Reload the correct language or de-select the second language.
|