Allen Bradley Kinetix 5300 Servo Drive

Fault Code and MeaningCause and Remedy
F02

Motor Commutation Fault

Cause:

Motor Commutation Fault detected.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault (Not configurable).


F03

Motor Overspeed Factory Limit Fault

Cause:

Motor Overspeed Factory Limit Fault.

Note: The loss of A/B signals from a TTL encoder isn’t detected directly. Typically detected through excessive position/velocity error or motor overspeed.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault (Not configurable).


F04

Motor Overspeed User Limit Fault

Cause:

Motor Overspeed User Limit Fault.

Note: The loss of A/B signals from a TTL encoder isn’t detected directly.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold (Available in Velocity Control mode).

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F05

Motor Overtemperature Factory Limit Fault

Cause:

Motor Overtemperature Factory Limit Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Major Fault.


F07

Motor Thermal Overload Factory Limit Fault

Cause:

Motor Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable (Available in Velocity Control mode).

  • Fault Action: Major Fault.


F08

Motor Thermal Overload User Limit Fault

Cause:

Motor Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold (Available in Velocity Control mode).

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F09

Motor Phase Loss

Cause:

Motor Phase Loss detected.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F10

Inverter Overcurrent Fault

Cause:

Inverter Overcurrent Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F11

Inverter Overtemperature Factory Limit Fault

Cause:

Inverter Overtemperature Factory Limit Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Major Fault.


F13

Inverter Thermal Overload Factory Limit Fault

Cause:

Inverter Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Current Decel/Disable.

  • Fault Action: Major Fault.


F14

Inverter Thermal Overload User Limit Fault

Cause:

Inverter Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F15

Converter Overcurrent Fault

Cause:

Converter Overcurrent Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F18

Converter OverTemp Factory Limit Fault

Cause:

Converter OverTemp Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F20

Converter Thermal Overload Factory Limit Fault

Cause:

Converter Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F21

Converter Thermal Overload User Limit Fault

Cause:

Converter Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F23

AC Single Phase Loss Fault

Cause:

AC Single Phase Loss Fault.



Remedy:


  • Best Available Stopping Action: Decel/Disable.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F25

Pre-charge Failure Fault

Cause:

Pre-charge Failure Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F29

Bus Regulator Thermal Overload Factory Limit Fault

Cause:

Bus Regulator Thermal Overload Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F30

Bus Regulator Thermal Overload User Limit Fault

Cause:

Bus Regulator Thermal Overload User Limit Fault.



Remedy:


  • Best Available Stopping Action: Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F31

Bus Regulator Failure

Cause:

Bus Regulator Failure.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F33

Bus Undervoltage Factory Limit Fault

Cause:

Bus Undervoltage Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


F34

Bus Undervoltage User Limit Fault

Cause:

Bus Undervoltage User Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F35

Bus Overvoltage Factory Limit Fault

Cause:

Bus Overvoltage Factory Limit Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F41

Feedback Signal Noise FL

Cause:

Feedback Signal Noise FL.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F43

Feedback Signal Loss FL

Cause:

Feedback Signal Loss FL.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F44

Feedback Signal Loss UL

Cause:

Feedback Signal Loss UL.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F45

Motor Feedback Data Loss Factory Limit Fault

Cause:

Motor Feedback Data Loss Factory Limit Fault.

Note: Applies to Hiperface feedback devices.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F46

Motor Feedback Data Loss User Limit Fault

Cause:

Motor Feedback Data Loss User Limit Fault.

Note: Applies to all compatible feedback devices.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F47

Feedback Device Failure

Cause:

Feedback Device Failure.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


F49

Brake Slip Exception

Cause:

Brake Slip Exception.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F50

Hardware Overtravel – Positive

Cause:

Hardware Overtravel – Positive.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F51

Hardware Overtravel – Negative

Cause:

Hardware Overtravel – Negative.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F54

Excessive Position Error Fault

Cause:

Excessive Position Error Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F55

Excessive Velocity Error Fault

Cause:

Excessive Velocity Error Fault.



Remedy:


  • If #589 vertical load control: Current Decel/Disable.

  • If not #589 vertical load control: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F56

Overtorque Limit Fault

Cause:

Overtorque Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F57

Undertorque Limit Fault

Cause:

Undertorque Limit Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Hold.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


F61

Enable Input Deactivated

Cause:

Enable Input Deactivated.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc02

Motor Voltage Mismatch Fault

Cause:

Motor Voltage Mismatch Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc05

Feedback Battery Loss Fault

Cause:

Feedback Battery Loss Fault.

Note: Applies to only Kinetix TLP or Kinetix TLY-Axxxx-B encoders.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


Fc06

Feedback Battery Low Fault

Cause:

Feedback Battery Low Fault.

Note: Applies to only Kinetix TLP or Kinetix TLY-Axxxx-B encoders.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc07

Feedback Incremental Count Error Exception

Cause:

Feedback Incremental Count Error Exception.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


Fc16

PWM Frequency Reduced Exception

Cause:

PWM Frequency Reduced Exception.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Configurable (Ignore, Alarm, Minor Fault, Major Fault).


Fc26

Runtime Error

Cause:

Runtime Error.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


nF01

Control Connection Update Fault

Cause:

Control Connection Update Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF02

Processor Watchdog Fault

Cause:

Processor Watchdog Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


nF05

Clock Skew Fault

Cause:

Clock Skew Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF06

Lost Controller Connection Fault

Cause:

Lost Controller Connection Fault.



Remedy:


  • Action: Programmable per Connection Loss Stopping Action.

  • Fault Action: Major Fault.


nF07

Clock Sync Fault

Cause:

Clock Sync Fault.



Remedy:


  • Best Available Stopping Action: Ramped Decel/Disable.

  • Fault Action: Major Fault.


nF09

Duplicate IP Address Fault

Cause:

Duplicate IP Address Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.


SF09

Guard Stop Input Fault

Cause:

Guard Stop Input Fault.



Remedy:


  • Best Available Stopping Action: Disable/Coast.

  • Fault Action: Major Fault.