Lenze SMD Drive Fault Codes:
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 50.0 (e.g.) Present output frequency | Cause: Trouble free operation. Remedy: (None required) |
| OFF Stop (outputs U, V, W inhibited) | Cause: LOW signal at terminal 28. Remedy: Set terminal 28 to HIGH. |
| StP Output frequency = 0 Hz (outputs U, V, W inhibited) | Cause:
Remedy:
|
| br DC-injection brake active | Cause: DC-injection brake activated:
Remedy: Deactivate DC-injection brake:
|
| CL Current limit reached | Cause: Controllable overload. Remedy: Automatically (see C22). |
| LU Undervoltage on DC bus | Cause: Mains voltage too low. Remedy: Check mains voltage. |
| dEC Overvoltage on DC bus during deceleration (warning) | Cause: Excessively short deceleration time (C13, c03). Remedy: Automatically if overvoltage < 1 s, OU if overvoltage > 1 s. |
| nEd No access to code | Cause: Can only be changed when the controller is in OFF. Remedy: Set terminal 28 to LOW. |
| cF / GF Data on EPM not valid | Cause:
Remedy:
|
| F1 EPM error | Cause: EPM missing or defective. Remedy: Power down and replace EPM. |
| CFG Digital inputs not uniquely assigned | Cause:
Remedy:
|
| EEr External error | Cause: Digital input “TRIP set” is active. Remedy: Remove external error. |
| F2…F0, JF Internal fault | Cause: Internal drive fault. Remedy: Please contact Lenze. |
| LC Automatic start inhibited | Cause: c42 = 0. Remedy: LOW-HIGH signal change at terminal 28. |
| OC1 Short-circuit or overload | Cause:
Remedy:
|
| OC2 Earth fault | Cause:
Remedy:
|
| OC6 Motor overload (I²t overload) | Cause: Motor is thermally overloaded, due to:
Remedy:
|
| OH Controller overtemperature | Cause: Controller too hot inside. Remedy:
|
| OU Overvoltage on DC bus | Cause:
Remedy:
|
| rSt Faulty auto-TRIP reset | Cause: More than 8 errors in 10 minutes. Remedy: Depends on the error. |
| Sd5 Loss of 4-20 mA reference | Cause: 4-20 mA signal is below 2 mA (C34 = 4). Remedy: Check signal/signal wire. |
| SF Single phase fault | Cause: A mains phase has been lost. Remedy: Check mains voltage. |