2250 CiA: Continuous overcurrent (inside the device) |
Cause: Classification: Error
Remedy:
- Check motor and wiring for short circuits.
- Check brake resistor and wiring.
- Check motor circuit (delta connection, star connection).
- Check setting of the motor data.
|
2320 Short circuit or earth leakage on motor side |
Cause: Classification: Error
Remedy:
- Check motor cable.
- Check the length of the motor cable.
- Use shorter or lower-capacitance motor cable.
|
2340 CiA: Short circuit (inside the device) |
Cause: Classification: Error
Remedy:
- Check motor cable for short circuit.
|
2350 CiA: i²*t overload (thermal state) |
Cause: Classification: Error
Remedy:
- Check drive sizing.
- Check machine/driven mechanics for excessive load.
- Check setting of the motor data.
- Reduce values for slip compensation (0x2B09:001, 0x2B09:002) and oscillation damping (0x2B0A:001, 0x2B0A:002).
|
2382 Error – device utilization (Ixt) too high |
Cause: Classification: Error
Remedy:
- Check drive sizing.
- Reduce maximum overload current of the inverter (0x6073).
- In case of high mass inertias, reduce maximum overload current of the inverter (0x6073) to 150 %.
|
2383 Warning – device utilization (Ixt) too high |
Cause: Classification: Warning
Remedy:
|
3120 Mains phase fault |
Cause: Classification: Error
Remedy:
- Check mains connection wiring.
- Check fuses.
|
3210 Error – DC bus overvoltage |
Cause: Classification: Error
Remedy:
- Reduce dynamic performance of the load profile.
- Check mains voltage.
- Check settings for the brake energy management.
|
3211 Warning: DC-bus overvoltage |
Cause: Classification: Warning
Remedy:
- (See Error 3210 for typical checks)
|
3220 Error – DC-bus undervoltage |
Cause: Classification: Trouble
Remedy:
- Check mains voltage.
- Check fuses.
- Check DC-bus voltage (0x2D87).
- Check mains settings.
|
3221 Warning: DC bus undervoltage |
Cause: Classification: Warning
Remedy:
- (See Error 3220 for typical checks)
|
3222 DC-bus voltage too low for switch-on |
Cause: Classification: Warning
Remedy:
- Check mains voltage.
- Check fuses.
- Check mains settings.
|
4210 Error – power section overtemperature |
Cause: Classification: Error
Remedy:
- Check mains voltage.
- Ensure sufficient cooling of the device (display of heatsink temperature in 0x2D84:001).
- Clean fan and ventilation slots. If required, replace fan.
- Reduce switching frequency (0x2939).
|
4281 Warning – heatsink fan |
Cause: Classification: Warning
Remedy:
- Clean fan and ventilation slots. If required, replace fan. The fans can be unlocked via locking hooks and can then be removed.
|
4310 Motor overtemperature |
Cause: Classification: Error
Remedy:
- Check drive sizing.
- Check motor temperature sensor and wiring at X105/T1+T2 or X109/T1+T2.
|
5112 24 V supply critical |
Cause: Classification: Warning
Remedy:
- Check optional external auxiliary supply on X100.1/24E.1, if connected.
- Check mains voltage.
|
5180 24 V supply overload |
Cause: Classification: Warning
Remedy:
- Check 24 V output and digital outputs for earth fault or overload.
|
6280 Trigger/functions connected incorrectly |
Cause: Classification: Trouble
Remedy:
- Check and correct the assignment of the triggers to the functions.
- In network control, the two functions “Inverter enable” (0x2631:001) and “Start” (0x2631:002) can also be set to “Constant TRUE [1]” to start the motor.
|
7180 Motor overcurrent |
Cause: Classification: Error
Remedy:
- Check motor load.
- Check drive sizing.
- Adapt set error threshold (0x2D46:001).
|
FF06 Motor overspeed |
Cause: Classification: Error
Remedy:
- Adapt the maximum motor speed (0x6080) and the error threshold (0x2D44:001).
|
FF37 Automatic start disabled |
Cause: Classification: Error
Remedy:
- Deactivate start command and reset error.
|