LS Electric iV5L Drive

Fault Code and MeaningCause and Remedy
Over Current

Priority: 4
Type: Latch

Cause:

Displayed when inverter output current exceeds the specified fault current.



Remedy:

Refer to detailed troubleshooting section in manual.
Ground Fault

Priority: 3
Type: Latch

Cause:

Displayed when a ground fault occurs in the inverter’s output, and current flow to ground exceeds the specified level.



Remedy:

Refer to detailed troubleshooting section in manual.
Over Voltage

Priority: 5
Type: Latch

Cause:

Displayed when the internal DC voltage exceeds the specified value (820 VDC).



Remedy:

Refer to detailed troubleshooting section in manual.
Low Voltage

Priority: 9
Type: Level

Cause:

Displayed when the internal DC voltage is less than the specified value (360 VDC).



Remedy:

Refer to detailed troubleshooting section in manual.
Over Load

Priority: 12
Type: Latch

Cause:

Displayed when the inverter’s output current exceeds the specified motor rated current and overload trip time.



Remedy:

Refer to detailed troubleshooting section in manual.
Inv OLT

Priority: 16
Type: Latch

Cause:

Displayed when the inverter has detected an overload and resultant overheating condition based on inverse time-limit thermal characteristics. Allowable overload rates for the inverter are 150% for 1 min.



Remedy:

Refer to detailed troubleshooting section in manual.
InvOver Heat

Priority: 10
Type: Latch

Cause:

Displayed when the temperature of the inverter heat sink exceeds the specified value.



Remedy:

Refer to detailed troubleshooting section in manual.
InvThem OP

Priority: 19
Type: Latch

Cause:

Displayed when the inverter thermistor detects a low temperature.



Remedy:

Refer to detailed troubleshooting section in manual.
MotOver Heat

Priority: 18
Type: Latch

Cause:

Displayed when the motor temperature exceeds 130°C.



Remedy:

Refer to detailed troubleshooting section in manual.
MotThem Err

Priority: 20
Type: Latch

Cause:

Displayed when a motor thermistor error occurs in the inverter thermistor.



Remedy:

Refer to detailed troubleshooting section in manual.
E-Thermal

Priority: 11
Type: Latch

Cause:

Displayed when internal electronic protection detects a high temperature condition at the motor.



Remedy:

Refer to detailed troubleshooting section in manual.
External-B

Priority: 14
Type: Latch

Cause:

Displayed when an external fault signal is generated.



Remedy:

Refer to detailed troubleshooting section in manual.
Arm Short / Arm Short-DB

Priority: 1
Type: Latch

Cause:

Displayed when IGBT Arm or output fault occurs. Arm Short-DB is only displayed on the 11-22 kW models.



Remedy:

Refer to detailed troubleshooting section in manual.
Fuse Open

Priority: 2
Type: Latch

Cause:

Displayed when circuit protection is activated by an IGBT fault.



Remedy:

Refer to detailed troubleshooting section in manual.
Encoder Err

Priority: 8
Type: Latch

Cause:

Displayed when an encoder signal error occurs.



Remedy:

Refer to detailed troubleshooting section in manual.
(No Display Name / General)

Priority: –
Type: –

Cause:

Displayed when an inconsistent motor error time is detected when compared to the PRT_11 setting.



Remedy:

Refer to detailed troubleshooting section in manual.
BX

Priority: –
Type: Latch

Cause:

Displayed when the inverter output is blocked by a signal from the multifunction terminal.



Remedy:

Refer to detailed troubleshooting section in manual.
Over Speed

Priority: 21
Type: Latch

Cause:

Displayed when the motor speed exceeds the specified maximum speed.



Remedy:

Refer to detailed troubleshooting section in manual.
COM Error

Priority: –
Type: Fatal

Cause:

Displayed when communication between the inverter and the keypad is unavailable.



Remedy:

Refer to detailed troubleshooting section in manual.
HW-Diag

Priority: 13
Type: Latch

Cause:

Displayed when a CPU error is detected.



Remedy:

Refer to detailed troubleshooting section in manual.
EEP Error

Priority: –
Type: Latch

Cause:

Displayed when a data saving error occurs.



Remedy:

Refer to detailed troubleshooting section in manual.
FAN Error

Priority: 6
Type: Latch

Cause:

Displayed when a cooling fan error is detected.



Remedy:

Refer to detailed troubleshooting section in manual.
BatRun Fault

Priority: 7
Type: Latch

Cause:

Displayed when operation signals are lost during a battery power operation.



Remedy:

Refer to detailed troubleshooting section in manual.
Input PO

Priority: 17
Type: Latch

Cause:

Displayed when a single phase of a 3-phase power supply is interrupted while the inverter is under load.



Remedy:

Refer to detailed troubleshooting section in manual.
Output PO

Priority: 15
Type: Latch

Cause:

Displayed when the inverter does not produce an output current.



Remedy:

Refer to detailed troubleshooting section in manual.
SpdDev Err

Priority: 26
Type: Latch

Cause:

Displayed when the difference between the motor speed and command speed is more than the specified value.



Remedy:

Refer to detailed troubleshooting section in manual.
Low Voltage2

Priority: 24
Type: Latch

Cause:

Displayed when the internal DC voltage is less than the specified value during inverter operation.



Remedy:

Refer to detailed troubleshooting section in manual.
SAFETY A/B

Priority: 25
Type: Latch/Level

Cause:

Displayed when there is a safety terminal wiring fault on the control board. The response can be set at either Latch or Level.



Remedy:

Refer to detailed troubleshooting section in manual.
A3 Safety

Priority: 23
Type: Latch

Cause:

Displayed when an A3 Safety error is detected at a multifunction input.



Remedy:

Refer to detailed troubleshooting section in manual.
ADC Error

Priority: 27
Type: Fatal

Cause:

Displayed when current calibration is incorrect when power is initially supplied to the inverter.



Remedy:

Refer to detailed troubleshooting section in manual.
Flr/FHM Data

Priority: 22
Type: Latch

Cause:

Displayed when a floor height data error is detected or a floor height measurement failure occurs. Available only when the exclusive elevator mode is used.



Remedy:

Refer to detailed troubleshooting section in manual.
SINCOS Open

Priority: 28
Type: Latch

Cause:

Displayed when EnDat signals Sin-, Cos-, Sin+, and Cos+ are not connected to a single or multiple lines.



Remedy:

Refer to detailed troubleshooting section in manual.
ENDAT ERROR

Priority: 29
Type: Latch

Cause:

Displayed when EnDat signals for the Clock or Data lines are not connected or a communication error is detected.



Remedy:

Refer to detailed troubleshooting section in manual.