cL1 ADI1 loss |
Cause: Loss of the current reference on analog input ADI1.
Remedy:
- Check that current is > 3 mA.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
cL2 ADI2 loss |
Cause: Loss of the current reference on analog input ADI2.
Remedy:
- Check that current is > 3 mA.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
cL3 ADIO3 loss |
Cause: Loss of the current reference on analog input ADIO3.
Remedy:
- Check that current is > 3 mA.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
EEF EEPROM fail. |
Cause: Drive rating does not match with XPressKey.
Remedy:
- Return to default factory settings (see 65).
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
enC2 Encoder rot |
Cause: The measured position does not vary (the encoder is incorrectly connected or not supplied with power or the shaft is not turning).
Remedy:
- Check encoder connections.
- Check the motor rotation is normal.
|
EnC1 U sign. loss |
Cause: Loss of channel U.
Remedy:
- Check the speed feedback.
- Replace the encoder.
|
EnC2 V sign. loss |
Cause: Loss of channel V.
Remedy:
- Check the encoder voltage and connections.
|
EnC3 W sign. loss |
Cause: Loss of channel W.
Remedy:
- Check the encoder voltage and connections.
|
Fbus Fieldbus loss |
Cause: Disconnection of the fieldbus.
Remedy:
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
- Check fieldbus connections and status.
|
It.AC Motor I²t |
Cause: Motor overload I x t.
Remedy:
- Read the battery value in 4.19.
- Check that the motor is not overloaded.
- Adjust the rated speed.
- Check that the motor rated current is correctly set (06).
- Speed feedback: check the coupling, and check that the signal is not disturbed.
- Check the number of motor poles in 62.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
It.br Brak. resist. |
Cause: Braking resistor overload I x t.
Remedy:
- Read the battery value in 10.39.
- Increase the resistor ohmic value.
- Check that 10.30 and 10.31 are set correctly (braking cycle too long).
- Check the resistor wiring.
- Check the integrated transistor.
|
Oht1 Dv over heat |
Cause: IGBT overheating (sensor).
Remedy:
- Reduce the motor load, the cycle, the switching frequency and the acceleration and deceleration ramps.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
Oht2 BR over heat |
Cause: Internal resistor overheating (sensor).
Remedy:
- Reduce the switching frequency.
- Reduce the cycle and the motor load.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
OI.AC Over current |
Cause: Overcurrent at drive output.
Remedy:
- Check motor insulation and connection.
- Increase acceleration and deceleration rates.
- Check feedback devices.
- Check motor cable length.
- Reduce the speed controller gains 29 (3.10), 30 (3.11) and 3.12.
- If not already set, perform an autotune 63 = 2.
- Reduce current controller gains 31 (4.13) and 32 (4.14).
|
OIbr Brak.IGBT |
Cause: IGBT braking overcurrent.
Remedy:
- Check the resistor insulation.
- Correct the short-circuit at the resistor output.
- Set a higher resistor ohmic value.
|
Old1 24V over Id |
Cause: Overload on +24V source or logic output.
Remedy:
- Check the total current consumption.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
OSP Over speed |
Cause: Overspeed.
Remedy:
- The speed is higher than 1.2 times the value of 02.
- Check that the load is not driving.
- Check that the overspeed threshold has been set correctly.
- Adjust the speed loop gains.
- Set a longer deceleration time.
|
OU DC over volt |
Cause: DC bus overvoltage.
Remedy:
- Provide a braking resistor (optional). If a resistor is already connected, reduce its value (within permitted limits).
- Check that the mains supply is not disturbed.
- Check the motor insulation.
- Set a longer deceleration time in 04.
- Check the deceleration mode.
|
ph In Ph. loss |
Cause: Phase loss. Note: The loss of one phase can only be detected if the active current is between 50% and 100% of the rated value.
Remedy:
- Check the mains supply (3 phases present and balanced).
- Check the level of supply voltage (at full load).
|
Ph.AC Out Ph. loss |
Cause: Motor phase loss.
Remedy:
- Check the connection of phases U, V and W in both the motor and the drive.
|
rot A/B reversed |
Cause: The a, b, a\, b\ signals are the wrong way round.
Remedy:
- Reverse 2 motor phases or 2 encoder channels.
|
rS Stator res. |
Cause: Stator resistance measurement fault.
Remedy:
- Adapt the drive power to that of the motor.
- Check the connection of the motor cables.
|
SCL COM loss |
Cause: Serial link fault.
Remedy:
- Replace the keypad or the cable.
- Check the connectors between the keypad and the drive.
- Check that the cable is not damaged.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
Secd Sec.disable |
Cause: Secure input fault.
Remedy:
- Give a stop command before enabling the drive.
|
Th Motor PTC |
Cause: Motor sensor trip.
Remedy:
- Check the motor load.
- Reduce the level of overload.
- Check the motor cooling and the ambient temperature.
- Check the wiring of the ADI2 terminal on the control terminal block.
- If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
tr01 – tr10 User 1 – 10 |
Cause: User fault 1 through 10 via logic input or serial link.
Remedy:
- Check logic inputs or serial communications.
- For tr05, tr10: If 10.37 = 1 (Ctld), the drive decelerates the motor without tripping.
|
tun3 UVW revers. |
Cause: The u, v, w switching signals are the wrong way round.
Remedy:
- Check encoder and motor connections.
|
tun4 U sign.miss. |
Cause: Some signals are present, but U is missing.
Remedy:
- Check encoder connections.
|
tun5 V sign.miss. |
Cause: Some signals are present, but V is missing.
Remedy:
- Check encoder connections.
|
tun6 W sign.miss. |
Cause: Some signals are present, but W is missing.
Remedy:
- Check encoder connections.
|
tun7 Pole count |
Cause: The number of pairs of poles set is incorrect (the revolutions measured mechanically and electrically are inconsistent).
Remedy:
- Check encoder lines per revolution.
- Verify 5.11 (62) “number of motor poles” setting.
|
tunE Autotun. fail |
Cause: Autocalibration error.
Remedy:
- Drive set to fault mode during the autocalibration phase.
- The Stop key has been pressed.
- The SDI2 contact has been opened during the autocalibration phase.
|
UU Under volt. |
Cause: DC bus undervoltage.
Remedy:
|